#1888 Controlled Impedance Flat Ribbon IDC - UL Style 2651 · VW-1
|
Available to Order
Product Options
| |
| |
|
Controlled Impedance Flat Ribbon IDC
UL Style 2651 · VW-1
Description: Each conductor is 28 AWG, 7 strand of 36 AWG T.C. with .010" nominal wall of extruded PVC insulation overall. Conductors are to provide .050" +/- .002", center to center conductor spacing allowing for nominal impedance of 105 Ohms (measured ground-signal-ground).
Cables are listed under UL style 2651 and meet UL VW-1 flame test.
Conductors separate cleanly and one has a red stripe for polarity.
Because of controlled center to center spacing, cables may be mass terminated with insulation displacement connectors designed for .050" spacing of conductors.
Crosstalk is also controllable.
| Controlled Impedance Flat Ribbon IDC |
DABURN
Cat. No. |
No. Of
Cond. |
Nom. Width A |
Nom. Span B |
| IN. |
MM. |
IN. |
MM. |
| 1888/9 |
9 |
.45 +/- .01 |
11.43 |
.40 +/- .007 |
10.16 |
| 1888/10 |
10 |
.50 +/- .01 |
12.70 |
.45 +/- .007 |
11.43 |
| 1888/14 |
14 |
.70 +/- .01 |
17.78 |
.65 +/- .007 |
16.51 |
| 1888/15 |
15 |
.75 +/- .01 |
19.05 |
.70 +/- .007 |
17.78 |
| 1888/16 |
16 |
.80 +/- .01 |
20.32 |
.75 +/- .009 |
19.05 |
| 1888/20 |
20 |
1.00 +/- .02 |
25.40 |
.95 +/- .009 |
24.13 |
| 1888/24 |
24 |
1.20 +/- .02 |
30.48 |
1.15 +/- .009 |
29.21 |
| 1888/25 |
25 |
1.25 +/- .02 |
31.75 |
1.20 +/- .009 |
30.48 |
| 1888/26 |
26 |
1.30 +/- .02 |
33.02 |
1.25 +/- .009 |
31.75 |
| 1888/34 |
34 |
1.70 +/- .02 |
43.18 |
1.65 +/- .009 |
41.91 |
| 1888/37 |
37 |
1.85 +/- .02 |
46.99 |
1.80 +/- .009 |
45.72 |
| 1888/40 |
40 |
2.00 +/- .02 |
50.80 |
1.95 +/- .011 |
49.53 |
| 1888/50 |
50 |
2.50 +/- .02 |
63.50 |
2.45 +/- .011 |
62.23 |
| 1888/60 |
60 |
3.00 +/- .02 |
76.20 |
2.95 +/- .011 |
74.93 |
| 1888/64 |
64 |
3.20 +/- .02 |
81.28 |
3.15 +/- .011 |
80.01 |
|
Standard Put-Up: |
100' (30.48M); Larger packages available to order. |
|
Color: |
Gray with red polarity stripe. |
|
UL Style: |
2651. |
|
Flammability Rating: |
UL VW-1. |
|
AWG: |
28 (7/36) T.C. |
|
Nom. Wall: |
.010" (.25 mm). |
|
Height: |
.035 +/- .003" (.89 mm +/- .08). |
|
Center to Center Spacing: |
.050" +/- .002 (1.27 mm +/- .05) |
|
Dielectric Withstand Voltage: |
2000 VRMS. |
|
Insulation Resistance: |
1010 OHMS/10 Ft min. |
|
Capacity Nom: |
15 PF/FT. (G.S.G.) |
|
Propagation Delay: |
1.4 ns/ft. (G.S.G.) nom. |
|
Temperature Rating: |
105°C. |
|
Current Rating: |
1 AMP. |
|
Impedance: |
105 Ohms nom. (G.S.G.) |
|
Voltage Rating: |
300 VRMS. |
|
Each conductor stranded tinned copper, polyvinylchloride insulation. Conductors are bonded to form flat ribbon cable. They are individually color coded and separate easily for terminations.
|
Each conductor stranded tinned copper, polyvinylchloride insulation. Conductors are bonded to form flat ribbon cable. Conductors are color coded and separate easily for terminations.
|
Color coded, Each conductor is stranded T.C. with extruded PVC insulation, bonded together to form a flat ribbon cable. Conductors separate easily for clean terminations with standard wire connectors, jacks and pins.
|
MIL-W-16878 Type C - 1000V · UL 2555 -300 V · CSA 90°C - 300 V - Each conductor is stranded T.C. with extruded PVC insulation, bonded together to form a flat ribbon cable. Conductors separate easily for clean terminations with standard wire connectors.
|
UL Style 20424 · 300 Volts · VW-1 - Daburn FEP ribbon cable reduces crosstalk, compared to PVC constructions. It provides hi-fidelity and dense signal transmission with low dielectric constant. It has a low coefficient of friction.
| |
|
|
|