#1888 Controlled Impedance Flat Ribbon IDC - UL Style 2651 · VW-1
|
|
Available to Order
Product Options
| |
| |
|
Controlled Impedance Flat Ribbon IDC
UL Style 2651 · VW-1
Description: Each conductor is 28 AWG, 7 strand of 36 AWG T.C. with .010" nominal wall of extruded PVC insulation overall. Conductors are to provide .050" +/- .002", center to center conductor spacing allowing for nominal impedance of 105 Ohms (measured ground-signal-ground).
Cables are listed under UL style 2651 and meet UL VW-1 flame test.
Conductors separate cleanly and one has a red stripe for polarity.
Because of controlled center to center spacing, cables may be mass terminated with insulation displacement connectors designed for .050" spacing of conductors.
Crosstalk is also controllable.
| Controlled Impedance Flat Ribbon IDC |
DABURN
Cat. No. |
No. Of
Cond. |
Nom. Width W |
Nom. Span S |
| IN. |
MM. |
IN. |
MM. |
| 1888/9
|
9
|
.45 +/- .01
|
11.43
|
.40 +/- .007
|
10.16
|
| 1888/10
|
10
|
.50 +/- .01
|
12.70
|
.45 +/- .007
|
11.43
|
| 1888/14
|
14
|
.70 +/- .01
|
17.78
|
.65 +/- .007
|
16.51
|
| 1888/15
|
15
|
.75 +/- .01
|
19.05
|
.70 +/- .007
|
17.78
|
| 1888/16
|
16
|
.80 +/- .01
|
20.32
|
.75 +/- .009
|
19.05
|
| 1888/20
|
20
|
1.00 +/- .02
|
25.40
|
.95 +/- .009
|
24.13
|
| 1888/24
|
24
|
1.20 +/- .02
|
30.48
|
1.15 +/- .009
|
29.21
|
| 1888/25
|
25
|
1.25 +/- .02
|
31.75
|
1.20 +/- .009
|
30.48
|
| 1888/26
|
26
|
1.30 +/- .02
|
33.02
|
1.25 +/- .009
|
31.75
|
| 1888/34
|
34
|
1.70 +/- .02
|
43.18
|
1.65 +/- .009
|
41.91
|
| 1888/37
|
37
|
1.85 +/- .02
|
46.99
|
1.80 +/- .009
|
45.72
|
| 1888/40
|
40
|
2.00 +/- .02
|
50.80
|
1.95 +/- .011
|
49.53
|
| 1888/50
|
50
|
2.50 +/- .02
|
63.50
|
2.45 +/- .011
|
62.23
|
| 1888/60
|
60
|
3.00 +/- .02
|
76.20
|
2.95 +/- .011
|
74.93
|
| 1888/64
|
64
|
3.20 +/- .02
|
81.28
|
3.15 +/- .011
|
80.01
|
|
Standard Put-Up: |
100' (30.48M); Larger packages available to order.
|
|
Color: |
Gray with red polarity stripe.
|
|
UL Style: |
2651.
|
|
Flammability Rating: |
UL VW-1.
|
|
AWG: |
28 (7/36) T.C.
|
|
Nom. Wall: |
.010" (.25 mm).
|
|
Height: |
.035 +/- .003" (.89 mm +/- .08).
|
|
Center to Center Spacing: |
.050" +/- .002 (1.27 mm +/- .05)
|
|
Dielectric Withstand Voltage: |
2000 VRMS.
|
|
Insulation Resistance: |
1010 OHMS/10 Ft min.
|
|
Capacity Nom: |
15 PF/FT. (G.S.G.)
|
|
Propagation Delay: |
1.4 ns/ft. (G.S.G.) nom.
|
|
Temperature Rating: |
105°C.
|
|
Current Rating: |
1 AMP.
|
|
Impedance: |
105 Ohms nom. (G.S.G.)
|
|
Voltage Rating: |
300 VRMS.
|
|
UL Style 20424 · 300 Volts · VW-1 - Daburn FEP ribbon cable reduces crosstalk, compared to PVC constructions. It provides hi-fidelity and dense signal transmission with low dielectric constant. It has a low coefficient of friction.
|
Each conductor stranded tinned copper, polyvinylchloride insulation. Conductors are bonded to form flat ribbon cable. They are individually color coded and separate easily for terminations.
|
Color coded, Each conductor is stranded T.C. with extruded PVC insulation, bonded together to form a flat ribbon cable. Conductors separate easily for clean terminations with standard wire connectors, jacks and pins.
|
Each conductor stranded tinned copper, polyvinylchloride insulation. Conductors are bonded to form flat ribbon cable. Conductors are color coded and separate easily for terminations.
|
MIL-W-16878 Type C - 1000V · UL 2555 -300 V · CSA 90°C - 300 V - Each conductor is stranded T.C. with extruded PVC insulation, bonded together to form a flat ribbon cable. Conductors separate easily for clean terminations with standard wire connectors.
| |
|
|
|