|
Instrumentation
Two and three conductors, stranded bare copper, serve, rubber insulation, filer, wrap tough black jacket overall. Molded plug one end, free end stripped. Hanked. Suitable for replacement on machinery, tools, refrigerators, electronic devices.
|
One or more conductors, each conductor silver plated concentrically stranded copper wire. Type E, MIL-W-16878E/4 with .010" of extruded TFE insulation. Conductors are twisted and shielded with a 90% braided, silver plated copper shield coverage overall.
|
One or more conductors, each conducter is silver plated, concentrically stranded copper wire. Type E, MIL-W-16878E/4 extruded TFE .010" insulation on conductors, which are covered with silver plated braided copper shield providing a 90% shield coverage.
|
One or more conductors, each conducter silver plated concentrically stranded copper wire. Type E, MIL-W-16878E/4 with .010" of extruded TFE insulation. Conductors are twisted and shielded with a 90% braided, silver plated copper shield overall.
|
One or more conductors, each conducter silver plated, concentrically stranded copper wire. Conductors are insulated with type E per MIL-W-16878E/4 with .010" of extruded TFE insulation and twisted. Covered with Teflon® impreganted fiberglass braid jacket.
|
Each conductor silver plated stranded copper wire, Type E extruded TFE .010" insulation. Color coded, cabled, braided silver plated copper shield-90% coverage, FEP white Teflon® jacket overall. Temperature Rating: -65°C to +200°C. Voltage Rating: 600V.
|
Shielded & Unshielded - Single conductor #23 (7) Soft tinned copper conductors insulated with .010'" Soft PVC. Multi-Concuctor items: Conductors are twisted. For Shielded items: Conductors are twisted and shielded with braided tinned copper overall.
|
Conductors are parallel, stranded copper, insulated with an extruded soft formulation PVC .The insulation slits and strips easily. For low voltage applications. Operating Temperature: 80°C.
|
Conductors are parallel, stranded copper, color coded and clear polyvinylchloride insulation. Polarity is determined by TC/BC or by identification on one leg. Conductors separate quickly when split apart.
|
Each conductor stranded tinned copper, color coded PVC. Where indicated, T.C. braid shield, paired. Gray polyvinylchloride jacket overall. Used for station to station wiring to eliminate cross-talk.
|
UL APPROVED (105°C), 300V, 125°C, VW-1
Solid Silver plated, oxygen-free, high conductivity (OFHC) copper conductor, extruded Kynar [polyvinylidene fluoride] insulation. To UL style # 1422, #1423.
|
300V • 150°C • UL 1516, 1523 (105°C) • VW-1
Solid silver plated, oxygen-free, high conductivity (OFHC) copper conductor, Tefzel (a modified copolymer of ethylene and tetraflouroethylene) overall.
|
|
|
|