Unshielded - Shielded
Two and three conductors, stranded bare copper, serve, rubber insulation, filer, wrap tough black jacket overall. Molded plug one end, free end stripped. Hanked. Suitable for replacement on machinery, tools, refrigerators, electronic devices.
|
MIL-W-16878 - Plastic Jacket, 600V · 105°C - One or more conductors stranded tinned copper, PVC insulation, color coded, clear Nylon (polyamide) jacket. Conductors are cabled, overall braided tinned copper shield. (min. 90% coverage.).
|
Constructed with white foam polyethylene insulation, braided tinned copper shield, chrome gray vinyl jacket. The low loss foam polyethylene construction has lower capacitance and attenuation than standard polyethylene mike cables - as much as 50%.
|
Conductors are parallel, stranded copper, color coded and clear polyvinylchloride insulation. Polarity is determined by TC/BC or by identification on one leg. Conductors separate quickly when split apart.
|
Single conductor of stranded tinned copper (or tinned copper and Copperweld) covered with polyethylene insulation and a spiral (or a braided) tinned copper shield. Overall gray vinyl jacket.
|
2 Conductor #18 AWG Stranded Tinned Copper, insulated. Fillers where necessary. Braided tinned copper shield and black jacket overall.
Studio type heavy duty plastic, shielded microphone cable. The hi-gloss, abrasion resistant jacket.
|
Each conductor tinned copper, polyethylene insulation - color coded. Conductors are cabled with fillers, textile wrapped, tinned copper braided shield (unless otherwise noted), gray polyvinyl jacket overall.
|
Each conductor tinned copper, polyethylene insulation - color coded. Conductors are cabled with fillers, textile wrapped, tinned copper braided shield, gray polyvinyl jacket overall. Operating Temperature: -20°C to +80°C. 600 Volts.
|
UL Style 2464 - Individually Polyester Foil Shielded Pairs - Each conductor is #22 AWG solid tinned copper, insulated with .013" color coded, vinyl cabled in pairs. Each pair is shielded with aluminum polyester foil and stranded tinned copper drain wire.
|
U/L Style 2493 - Individually Polyester Foil Shielded Pairs RS 232 - Each conductor is #22 AWG stranded tinned copper, insulated with color coded, high density polyethylene and twisted into pairs. Each pair is shielded with aluminum polyester foil.
|
Four conductor #22 stranded tinned copper, color coded polypropylene insulation, aluminum mylar foil shield and stranded T. C. drain wire over one pair. Chrome vinyl jacket overall. Suitable for balanced systems, small O.D., less bulk.
|
UL Style 1108, 2095 · VW-1 · CL2 - Each conductor is tinned copper with plastic insulation. Conductors are color coded and twisted then wrapped with spiral tinned copper shielding. Jacket is gray polyvinylcholoride.
|
UL 2092, 2093, 2094† - Each conductor is stranded tinned copper-color coded with polyethylene insulation, conductors are twisted with an overall aluminum/polyester foil shield and drain. Gray PVC jacket. Drainwire provides quick and easy grounding.
|
UL STYLE 2095, 1108 · VW-1 · CL2 - Each conductor is stranded tinned copper with PVC insulation, color coded, twisted, braided tinned copper shield and an overall gray vinyl jacket. The braided tinned copper construction allows ease of pigtailing.
|
UL Style 2576 - VW-1 CL2 - Each conductor is #22 AWG solid tinned copper, with .010" wall vinyl plastic insulation. Conductors are color coded and twisted into pairs, cabled with a gray vinyl jacket overall.
|
U/L Style 2576 · CL2 · VW-1 - Each conductor is 22 AWG 7/30 tinned copper, with .010" wall of vinyl plastic insulation. Conductors are color coded and twisted into pairs, cabled with a gray vinyl jacket overall.
|
UL 2464 · VW-1 · CL2 - Each conductor #18 AWG stranded tinned copper, insulated with .018" color coded vinyl and twisted into pairs. The pairs are jacketed with abrasion resistant gray vinyl jacket. For use where larger conductors are indicated.
|
U/L Style 1007, 1581 · 80°C · 300V · VW-1 - Twisted pair and triple of tinned copper conductors insulated with vinyl insulation. No jacket. Operating Voltage:#22 AWG-300V(300V UL), #20 AWG-350V(300V UL),#18 AWG-400V(300V UL), #16 & #14 AWG-600V (300V UL)
|
STYLE 2905 · 80°C · 125 V · VW-1 · CL2 - Each conductor is stranded tinned copper with color coded plastic insulation. Conductors are twisted and covered by a gray vinyl jacket overall. Suitable for indoor and outdoor use.
|
Each conductor is #22 AWG 7/30 tinned copper with .010" wall of color coded plastic insulation. Conductors are twisted and covered by a gray vinyl jacket overall. Suitable for signal, P. A. systems, computers - for indoor and outdoor use.
| |
|
|
|