#1888 Controlled Impedance Flat Ribbon IDC - UL Style 2651 · VW-1
|
Product Options
Size: |
|
Put-Up: |
|
|
Controlled Impedance Flat Ribbon IDC UL Style 2651 · VW-1
Description: Each conductor is 28 AWG, 7 strand of 36 AWG T.C. with .010" nominal wall of extruded PVC insulation overall. Conductors are to provide .050" +/- .002", center to center conductor spacing allowing for nominal impedance of 105 Ohms (measured ground-signal-ground). IDC flat ribbon cables are listed under UL style 2651 and meet UL VW-1 flame test. Conductors separate cleanly and one has a red stripe for polarity. Because of controlled center to center spacing, cables may be mass terminated with insulation displacement connectors designed for .050" spacing of conductors. Crosstalk is also controllable.
DABURN Cat. No. |
No. Of Cond. |
Nom. Width W |
Nom. Span S |
IN. |
MM. |
IN. |
MM. |
1888/9 |
9 |
.45 +/- .01 |
11.43 |
.40 +/- .007 |
10.16 |
1888/10 |
10 |
.50 +/- .01 |
12.70 |
.45 +/- .007 |
11.43 |
1888/14 |
14 |
.70 +/- .01 |
17.78 |
.65 +/- .007 |
16.51 |
1888/15 |
15 |
.75 +/- .01 |
19.05 |
.70 +/- .007 |
17.78 |
1888/16 |
16 |
.80 +/- .01 |
20.32 |
.75 +/- .009 |
19.05 |
1888/20 |
20 |
1.00 +/- .02 |
25.40 |
.95 +/- .009 |
24.13 |
1888/24 |
24 |
1.20 +/- .02 |
30.48 |
1.15 +/- .009 |
29.21 |
1888/25 |
25 |
1.25 +/- .02 |
31.75 |
1.20 +/- .009 |
30.48 |
1888/26 |
26 |
1.30 +/- .02 |
33.02 |
1.25 +/- .009 |
31.75 |
1888/34 |
34 |
1.70 +/- .02 |
43.18 |
1.65 +/- .009 |
41.91 |
1888/37 |
37 |
1.85 +/- .02 |
46.99 |
1.80 +/- .009 |
45.72 |
1888/40 |
40 |
2.00 +/- .02 |
50.80 |
1.95 +/- .011 |
49.53 |
1888/50 |
50 |
2.50 +/- .02 |
63.50 |
2.45 +/- .011 |
62.23 |
1888/60 |
60 |
3.00 +/- .02 |
76.20 |
2.95 +/- .011 |
74.93 |
1888/64 |
64 |
3.20 +/- .02 |
81.28 |
3.15 +/- .011 |
80.01 |
Standard Put-Up:
|
100' (30.48M); Larger packages available to order. |
Color:
|
Gray with red polarity stripe. |
UL Style:
|
2651. |
Flammability Rating:
|
UL VW-1. |
AWG:
|
28 (7/36) T.C. |
Nom. Wall:
|
.010" (.25 mm). |
Height:
|
.035 +/- .003" (.89 mm +/- .08). |
Center to Center Spacing:
|
.050" +/- .002 (1.27 mm +/- .05) |
Dielectric Withstand Voltage:
|
2000 VRMS. |
Insulation Resistance:
|
1010 OHMS/10 Ft min. |
Capacity Nom:
|
15 PF/FT. (G.S.G.) |
Propagation Delay:
|
1.4 ns/ft. (G.S.G.) nom. |
Temperature Rating:
|
105°C. |
Current Rating:
|
1 AMP. |
Impedance:
|
105 Ohms nom. (G.S.G.) |
Voltage Rating:
|
300 VRMS. |
|
UL Style 20424 · 300 Volts · VW-1 - Daburn FEP ribbon cable reduces crosstalk, compared to PVC constructions. It provides hi-fidelity and dense signal transmission with low dielectric constant. It has a low coefficient of friction.
|
Each conductor stranded tinned copper, polyvinylchloride insulation. Conductors are bonded to form flat ribbon cable. They are individually color coded and separate easily for terminations.
|
Color coded, Each conductor is stranded T.C. with extruded PVC insulation, bonded together to form a flat ribbon cable. Conductors separate easily for clean terminations with standard wire connectors, jacks and pins.
|
Each conductor stranded tinned copper, polyvinylchloride insulation. Conductors are bonded to form flat ribbon cable. Conductors are color coded and separate easily for terminations.
|
MIL-W-16878 Type C - 1000V · UL 2555 -300 V · CSA 90°C - 300 V - Each conductor is stranded T.C. with extruded PVC insulation, bonded together to form a flat ribbon cable. Conductors separate easily for clean terminations with standard wire connectors.
| |