Air Compressor

Design • Manufacturing • Programming • Testing • Installation • Technical Service


For an expert consultation:

973-831-9110
Office@sicocontrol.net
Control Panel System-Request for Proposal"

The UL 508A listed control panel is supplied in a NEMA 12 enclosure.

The panel includes circuit breakers for:

  • Short circuit protection
  • Control circuit transformers with primary and secondary fuses
  • Magnetic starters with overload relay for motor protection
  • HOA switches with run indication light for each pump
  • Alarm with visual and audible indication and dryer controls

The Programmable Logic Controller provides automatic operation, including lead/lag pump alternation.

The color touchscreen operator interface (HMI) display includes:

  • Compressor run indication
  • Accumulated run time
  • Pressure level
  • Dew point reading
  • CO level
  • Alarm conditions, and alarm history
  • Full dryer control is accessed through custom screens
Also included is access to the operation manual, wiring diagrams, and a maintenance/spare parts list.

The system provides the following audible and visual alarms: (alarms listed are not limited to the following)

    • Pressure transducer
    • Dew point
    • CO sensor failure
    • Over temperature condition for each pump
    • Pump failure
    • "Backup in use"
    • High dew point and High CO

The audible alarm can be acknowledged with the "Silence" button. All controls and alarms will function even if one of the compressors is shut down for maintenance or repairs.

The system provides dry contacts for remote alarm annunciation or optional connections to BMS systems utilizing BACnet, Modbus and Ethernet.

(Illustration shown is standard control panel offering for Duplex and above)

The Standard Control Panel Features:

4.3” Touchscreen HMI with screen displays inclusive of:

  • System status, system air pressure, dew point and CO values, and service alerts
  • Visual/audible alarm indications with isolated dry contacts for all standard remote alarms
  • Event log recording of alarms and system activity
  • NEMA 12 control panel enclosure

    Circuit breaker protection for each pump with door interlocks
    Control circuit transformers with primary and secondary fuses
    Magnetic starters with overload protection relay
    Pressure level controlled by a pressure transducer
    Pressure switches are provided as a back-up to the pressure transducer in the event of failure

OPTIONAL: 7” Touchscreen HMI with screen displays as listed above.

Other Options: