Browse Categories
PayPal Accept credit cards with QuickBooks Payments
Mailing Lists

HRCD20 Series DC-DC Converters for Railway Applications


Price (Each): Call or e-mail for quotes or to order.
Available to Order
Item Number: HRCD20

HRCD20 Series 20-watt DC-DC converters for railway applications feature a 12:1 wide input range, low standby power, 3,000V AC reinforced insulation and no minimum load. Built-in safeguards include an inrush current limiting feature and an enhanced hold-up function as well as reverse polarity, overcurrent, overvoltage, short circuit, undervoltage and over-temperature protections. The converters also provide an internal EN 55032 Class B filter and operate at up to 5,000 meters in altitude. HRCD20 DC-DC converters meet the IEC/EN/UL 62368-1 safety standard and are compliant with RoHS and REACH regulations. Customers may choose a chassis-mount or DIN rail version.

HRCD20 Series Specification Sheet PDF

Daburn Part
Number

Input Voltage Range
Vac

Output Voltage
Vdc
Output Current at Full Load
mA
Input Current at No Load
mA
Efficiency
%
Maximum Capacitor Load
µF

HRCD20-72S5

14-160 5 4000 15 85 5000

HRCD20-72S5.1

14-160 5.1 4000 15 85 5000

HRCD20-72S12

14-160 12 1670 15 85 850

HRCD20-72S15

14-160 15 1330 15 85 700

HRCD20-72S24

14-160 24 835 15 85 200

HRCD20-72-12

14-160 ±12 ±833 15 85 ±500

HRCD20-72-15

14-160 ±15 ±667 15 85 ±300



Input and Output Specifications:


INPUT

  • Operating Input Voltage Range:
    • 14-160Vdc
  • Input Fuse: 3.15A, Time-Lag
  • In-rush current: 15A
  • Start up voltage: 14Vdc
  • Shutdown voltage: 10-13Vdc
  • Start up time: 50ms, Constant resistive load, Power up
  • Input surge voltage: 200Vdc Max., 1 second Max.
  • Interruption of power supply: 10 Min., EN50155 Class S2
  • Remote ON/OFF:
    • Positive logic, DC-DC ON: Open or 3~12Vdc
    • Positive logic, DC-DC OFF: Short or 0~1.2Vdc
    • Input current of Ctrl pin: ±0.5mA
    • Remote off input current: 2.5mA

OUTPUT

  • Voltage accuracy: ±1%
  • Line regulation: ±1%, Low Line to High Line at Full Load
  • Load regulation:
    • 5 Vout, 5.1 Vout: ±1.5%
    • 12 Vout, 15 Vout, 24 Vout: ±1%
  • Cross regulation: ±5%, Asymmetrical Load 25%/100% FL, Dual
  • Voltage adjustability:
    • Single output, 12 Vout: ±10%
    • Others: -10Min., 20Max
  • Ripple and noise, Measured by 20MHz bandwidth:
    • 5Vout, 5.1Vout: 75 mVp-p
    • 12Vout, 15Vout: 100 mVp-p
    • 24Vout: 125 mVp-p
    • 12Vout, 15Vout: 100 mVp-p
  • Temperature coefficient: ±0.02 %°C
  • Transient response recovery time: 250µS
  • Over voltage protection:
    • 5, 5.1 Vout: 6.3-7.4 Vdc
    • 12 Vout: 13.5-19.6 Vdc
    • 15 Vout: 18.3-22.0 Vdc
    • 24 Vout: 29.1-32.5 Vdc
  • Output indicator: Green LED
  • Over Load Protection: Percent of Iout rated, Hiccup mode: 155%
  • Short Circuit Protection: Continuous, automatic recovery

More Specifications: 

 

GENERAL

  • Isolation Voltage:
    • Input to Output, 1 minute: 3,000Vac
    • Input (Output) to Case: 2,250Vac
  • Isolation Resistance: 500Vdc, 1GΩ
  • Isolation capacitance: 6,000 pF
  • Switching Frequency: 190-250kHz


ENVIRONMENTAL

  • Operating Ambient Temperature:
    • With derating: -40-100ºC
  • Over temperature protection, Case of DC/DC module: 115ºC
  • Storage Temperature Range:
    • -55-105ºC
  • Operating Altitude: 5000m
  • Thermal shock: MIL-STD-810F
  • Shock:
    • U: EN61373, MIL-STD-810F
    • U-DR: EN61373, IEC60068-2-27
  • Vibration:
    • U: EN61373, MIL-STD-810F
    • U-DR: EN61373, IEC60068-2-6
  • Relative Humidity: 5% to 95% RH

 

PHYSICAL

  • Safety approvals (Pending): IEC/ EN/ UL62368-1, EN50155, EN45545-2
  • Standard approvals (Pending): EN50155 EN45545-2
  • Chassis material: Aluminum
  • Weight: 95g (3.35oz)
  • MTBF: MIL-HDBK-217F, Full load, 1.003 x 106 hrs

 

 EMC CHARACTERISTICS

  • EMI:
    • EN55032, EN50121-3-2: Class B
  • EMS: EN55035, EN50121-3-2
  • ESD: EN61000-4-2, Air ±8kV and contact ±6kV, Perf. Criteria A
  • Radiated Immunity: EN61000-4-3, 20V/m, Perf. Criteria A
  • Fast Transient: EN61000-4-4, ±2kV, Perf. Criteria A
  • Surge: EN61000-4-5, EN55035:±1kV and EN50121-3-2:±2kV, Perf. Criteria A
  • Conducted Immunity: EN61000-4-6, 10 Vr.m.s, Perf. Criteria A
  • Power Frequency Magnetic Field: EN61000-4-8, 100 A/m continuous; 1000A/m 1 second, Perf. Criteria A

 

Product Reviews

(0 Ratings, 0 Reviews)