HRCD20 Series DC-DC Converters for Railway Applications
|
Price (Each): Call or e-mail for quotes or to order.
Available to Order
Item Number: HRCD20
|
HRCD20 Series 20-watt DC-DC converters for railway applications feature a 12:1 wide input range, low standby power, 3,000V AC reinforced insulation and no minimum load. Built-in safeguards include an inrush current limiting feature and an enhanced hold-up function as well as reverse polarity, overcurrent, overvoltage, short circuit, undervoltage and over-temperature protections. The converters also provide an internal EN 55032 Class B filter and operate at up to 5,000 meters in altitude. HRCD20 DC-DC converters meet the IEC/EN/UL 62368-1 safety standard and are compliant with RoHS and REACH regulations. Customers may choose a chassis-mount or DIN rail version.
HRCD20 Series Specification Sheet PDF
Daburn Part Number |
Input Voltage Range Vac
|
Output Voltage Vdc |
Output Current at Full Load mA |
Input Current at No Load mA |
Efficiency % |
Maximum Capacitor Load µF |
HRCD20-72S5
|
14-160 |
5 |
4000 |
15 |
85 |
5000 |
HRCD20-72S5.1
|
14-160 |
5.1 |
4000 |
15 |
85 |
5000 |
HRCD20-72S12
|
14-160 |
12 |
1670 |
15 |
85 |
850 |
HRCD20-72S15
|
14-160 |
15 |
1330 |
15 |
85 |
700 |
HRCD20-72S24
|
14-160 |
24 |
835 |
15 |
85 |
200 |
HRCD20-72-12
|
14-160 |
±12 |
±833 |
15 |
85 |
±500 |
HRCD20-72-15
|
14-160 |
±15 |
±667 |
15 |
85 |
±300 |
Input and Output Specifications:
INPUT
- Operating Input Voltage Range:
- Input Fuse: 3.15A, Time-Lag
- In-rush current: 15A
- Start up voltage: 14Vdc
- Shutdown voltage: 10-13Vdc
- Start up time: 50ms, Constant resistive load, Power up
- Input surge voltage: 200Vdc Max., 1 second Max.
- Interruption of power supply: 10 Min., EN50155 Class S2
- Remote ON/OFF:
- Positive logic, DC-DC ON: Open or 3~12Vdc
- Positive logic, DC-DC OFF: Short or 0~1.2Vdc
- Input current of Ctrl pin: ±0.5mA
- Remote off input current: 2.5mA
OUTPUT
- Voltage accuracy: ±1%
- Line regulation: ±1%, Low Line to High Line at Full Load
- Load regulation:
- 5 Vout, 5.1 Vout: ±1.5%
- 12 Vout, 15 Vout, 24 Vout: ±1%
- Cross regulation: ±5%, Asymmetrical Load 25%/100% FL, Dual
- Voltage adjustability:
- Single output, 12 Vout: ±10%
- Others: -10Min., 20Max
- Ripple and noise, Measured by 20MHz bandwidth:
- 5Vout, 5.1Vout: 75 mVp-p
- 12Vout, 15Vout: 100 mVp-p
- 24Vout: 125 mVp-p
- 12Vout, 15Vout: 100 mVp-p
- Temperature coefficient: ±0.02 %°C
- Transient response recovery time: 250µS
- Over voltage protection:
- 5, 5.1 Vout: 6.3-7.4 Vdc
- 12 Vout: 13.5-19.6 Vdc
- 15 Vout: 18.3-22.0 Vdc
- 24 Vout: 29.1-32.5 Vdc
- Output indicator: Green LED
- Over Load Protection: Percent of Iout rated, Hiccup mode: 155%
- Short Circuit Protection: Continuous, automatic recovery
More Specifications:
GENERAL
- Isolation Voltage:
- Input to Output, 1 minute: 3,000Vac
- Input (Output) to Case: 2,250Vac
- Isolation Resistance: 500Vdc, 1GΩ
- Isolation capacitance: 6,000 pF
- Switching Frequency: 190-250kHz
ENVIRONMENTAL
- Operating Ambient Temperature:
- Over temperature protection, Case of DC/DC module: 115ºC
- Storage Temperature Range:
- Operating Altitude: 5000m
- Thermal shock: MIL-STD-810F
- Shock:
- U: EN61373, MIL-STD-810F
- U-DR: EN61373, IEC60068-2-27
- Vibration:
- U: EN61373, MIL-STD-810F
- U-DR: EN61373, IEC60068-2-6
- Relative Humidity: 5% to 95% RH
PHYSICAL
- Safety approvals (Pending): IEC/ EN/ UL62368-1, EN50155, EN45545-2
- Standard approvals (Pending): EN50155 EN45545-2
- Chassis material: Aluminum
- Weight: 95g (3.35oz)
- MTBF: MIL-HDBK-217F, Full load, 1.003 x 106 hrs
EMC CHARACTERISTICS
- EMI:
- EN55032, EN50121-3-2: Class B
- EMS: EN55035, EN50121-3-2
- ESD: EN61000-4-2, Air ±8kV and contact ±6kV, Perf. Criteria A
- Radiated Immunity: EN61000-4-3, 20V/m, Perf. Criteria A
- Fast Transient: EN61000-4-4, ±2kV, Perf. Criteria A
- Surge: EN61000-4-5, EN55035:±1kV and EN50121-3-2:±2kV, Perf. Criteria A
- Conducted Immunity: EN61000-4-6, 10 Vr.m.s, Perf. Criteria A
- Power Frequency Magnetic Field: EN61000-4-8, 100 A/m continuous; 1000A/m 1 second, Perf. Criteria A
|
Product Reviews
|
|