MCWA6 Series DC-DC Converters
|
Available to Order
Item Number: MCWA6
|
The Polytron MCWA6 Series of single- and dual-output DC-DC converters deliver up to 6 watts of output, accept 2:1 input voltages of 9-18, 18-36 or 36-75 and require no minimum load. Designed for medical and industrial applications, the units provide 5,000V AC input to output 2xMOPP isolation with 8 millimeters of clearance and creepage insulation distance for patient safety. The DC-DC converters also feature 2 µA leakage current, low standby power, a built-in EN55032 Class A EMI filter and an operating altitude of 5,000 meters. Built-in safeguards include overcurrent, overvoltage, short circuit and undervoltage protections. The MCWA6 Series DC-DC converters meet IEC/EN/ANSI/AAMI ES 60601-1 and IEC/EN/UL 62368-1 safety standards and comply with RoHS and REACH regulations.
MCWA6 Series Specification Sheet PDF
Daburn Part Number |
Input Voltage Range Vdc |
Output Voltage Vdc |
Output Current at Full Load mA |
Input Current at No Load mA |
Efficiency (%) |
Maximum Capacitor Load µF |
MCWA6-12S5 |
9 ~ 18 |
5 |
1200 |
10 |
84 |
1500 |
MCWA6-12S12 |
9 ~ 18 |
12 |
500 |
10 |
87 |
260 |
MCWA6-12S15 |
9 ~ 18 |
15 |
400 |
10 |
86 |
210 |
MCWA6-24S5 |
18 ~ 36 |
5 |
1200 |
6 |
84 |
1500 |
MCWA6-24S12 |
18 ~ 36 |
12 |
500 |
6 |
87 |
260 |
MCWA6-24S15 |
18 ~ 36 |
15 |
400 |
6 |
87 |
210 |
MCWA6-48S5 |
36 ~ 75 |
5 |
1200 |
4 |
84 |
1500 |
MCWA6-48S12 |
36 ~ 75 |
12 |
500 |
4 |
87 |
260 |
MCWA6-48S15 |
36 ~ 75 |
15 |
400 |
4 |
86 |
210 |
MCWA6-12-5 |
9 ~ 18 |
±5 |
±600 |
15 |
83 |
±860 |
MCWA6-12-12 |
9 ~ 18 |
±12 |
±250 |
10 |
87 |
±150 |
MCWA6-12-15 |
9 ~ 18 |
±15 |
±200 |
14 |
86 |
±110 |
MCWA6-24-5 |
18 ~ 36 |
±5 |
±600 |
8 |
84 |
±860 |
MCWA6-24-12 |
18 ~ 36 |
±12 |
±250 |
6 |
86 |
±150 |
MCWA6-24-15 |
18 ~ 36 |
±15 |
±200 |
8 |
86 |
±110 |
MCWA6-48-5 |
36 ~ 75 |
±5 |
±600 |
4 |
83 |
±860 |
MCWA6-48-12 |
36 ~ 75 |
±12 |
±250 |
4 |
87 |
±150 |
MCWA6-48-15 |
36 ~ 75 |
±15 |
±200 |
4 |
85 |
±110 |
Input and Output Specifications:
|
INPUT
- Operating input voltage range, Vdc:
- 9 Min., 12 Typ., 18 Max.: 12Vin (nom)
- 18 Min., 24 Typ., 36 Max.: 24Vin (nom)
- 36 Min., 48 Typ., 75 Max.: 48Vin (nom)
- Start up voltage, Vdc:
- 9 Max.: 12Vin (nom)
- 18 Max.: 24Vin (nom)
- 36 Max.: 48Vin (nom)
- Shutdown voltage, Vdc:
- 7 Min., 8 Typ., 8.8 Max.: 12Vin (nom)
- 15 Min., 16 Typ., 17.5 Max.: 24Vin (nom)
- 31.5 Min., 33 Typ., 34.5 Max.: 48Vin (nom)
- Start up time, ms: 35 Typ., Power up, Constant resistive load
- Input surge voltage, Vdc:
- 25 Max.: 12Vin (nom), 3 seconds max.
- 50 Max.: 24Vin (nom)
- 100 Max.: 48Vin (nom)
- Input filter: Pi type
|
OUTPUT
- Voltage accuracy, %: ±1
- Line regulation, %: Low line to high line at full load
- Load regulation, %: No load to full load
- Cross regulation, %: ±5, Asymmetrical load 25%/100% FL, Dual
- Voltage adjustability, %:
- ±10: Single Output, 5Vout, 12Vout
- -10 Min., 20 Max.: Single output, 15Vout
- ±10: Dual output, ±5Vout, ±12Vout, ±15Vout
- Ripple and noise, mVp-p: Measured by 20MHz bandwidth, with a 10µF/25V X7R MLCC
- 50 Typ.: 5Vout
- 75 Typ.: 12Vout, 15Vout
- Temperature coefficient, %/ºC: ±0.02
- Transient response recovery time, μs: 250 Typ., 25% load step change
- Over voltage protection. Vdc:
- 5.6 Min., 7 Max.: Single, 5Vout
- 13.5 Min., 16 Max.: Single, 12Vout
- 18.3Min., 22 Max.: Single, 15Vout
- 5.6 Min., 7 Max.: Dual, 5Vout
- 13.5 Min., 18.2 Max.: Dual, 12Vout
- 17 Min., 22 Max.: Dual, 15Vout
- Over load protection, %: Percent of Iout rated, Hiccup mode: 150
- Short circuit protection: Continuous, automatic recovery
|
More Specifications:
|
GENERAL
- Isolation Voltage, Vac: 1 minute, input to output, reinforced insulation for 250VAC, 5,000 Min.
- Isolation resistance, GΩ: 500Vdc, 10 Min.
- Isolation capacitance, pF: 15 Typ., 17 Max.
- Switching frequency, kHz: 225 Min., 250 Typ., 275 Max.
- Clearance/Creepage, mm: 8 Min.
ENVIRONMENTAL
- Operating ambient temperature °C: With derating, -40 Min. +105 Max.
- Maximum case temperature, °C: +105 Max.
- Storage temperature range: -55 Min., 125 Max.
- Thermal impedance, °C/W: 18 Typ.
- Operating altitude, m: 5000 Max.
- Thermal shock: MIL-STD-810F
- Vibration: MIL-STD-810F
- Relative humidity: 5% to 95% RH
|
PHYSICAL
- Design meet safety standard: IEC/EN/ANSI/AAMI ES 60601-1,IEC/EN/UL 62368-1
- Dimensions: 1.25 × 0.8 × 0.41 inches, (31.8 × 20.3 × 10.5 mm), A Type, B Type
- Case material: Non-conductive black plastic
- Base material: Non-conductive black plastic
- Potting material: Silicone, (UL94 V-0)
- Weight: 13.5g (0.47oz)
- MTBF: 3.942 × 106 hrs, MIL-HDBK-217F, Full Load
EMC CHARACTERISTICS
- EMI:
- EN55011, EN55032, EN60601-1-2, Without external filter, Class A
- With external filter, Class B
- EMS: EN55035, EN60601-1-2
- ESD: EN61000-4-2, Air ±15kV and Contact ±8kV, Perf. Criteria A
- Radiated immunity: EN61000-4-3, 10V/m, Perf. Criteria A
- Fast transient: EN61000-4-4, ±2KV, Perf. Criteria A
- Surge: EN61000-4-5, Perf. Criteria A
- Conducted immunity: EN61000-4-6, 10Vr.m.s, Perf. Criteria A
- Power frequency magnetic field: EN61000-4-8, 100A/m continuous; 1000A/m 1 second, Perf. Criteria A
|
|
Product Reviews
|
|