Models:

Liquid Ring QT Pump Specifications

Pump
Horsepower

Capacity (SCFM) @ 19"Hg

System
Btu/hr

System
dB(A) Level

System FLA

Pump

System

208V

230V

460V

380V (50 Hz)

Duplex

3

14

14

7,635

73

18.9

17.4

10.7

8.8

5

21

21

12,725

76

31.2

28.2

15.9

18.3

5 [HC]

26

26

12,725

72

31.0

28.0

14.3

17.7

7.5

38

38

19,088

73

44.5

40.2

24.5

26.2

10

53

53

25,450

77

54.9

49.6

26.3

31.4

15

76

76

38,175

76

95.8

91.8

45.9

52.9

20

110

110

50,900

76

127.1

122.2

61.1

66.0

30

172

172

76,350

77

196.1

177.4

88.5

89.6

Triplex

3

14

27

15,270

75

28.3

26.0

16.0

13.2

5

21

42

25,450

78

46.8

42.3

23.8

27.5

5 [HC]

26

52

25,450

74

46.5

42.0

21.4

26.6

7.5

38

76

38,175

75

66.7

60.3

36.8

39.3

10

53

106

50,900

79

82.3

74.4

39.5

47.1

15

76

152

76,350

78

143.7

137.8

68.9

79.3

20

110

220

101,800

78

190.6

183.3

91.7

99.0

30

172

344

152,700

79

294.1

266.1

132.8

134.4

Quadraplex

3

14

41

22,905

76

37.7

34.7

21.4

17.6

5

21

63

38,175

79

62.4

56.3

31.8

36.6

5 [HC]

26

78

38,175

75

62.0

55.9

28.6

35.4

7.5

38

114

57,263

76

89.0

80.4

49.0

52.4

10

53

159

76,350

80

109.8

99.2

52.6

62.8

15

76

228

114,525

79

191.6

183.7

91.8

105.7

20

110

330

152,700

79

254.2

244.4

122.2

132.0

30

172

516

229,050

80

392.2

354.8

177.0

179.2

Notes:

• System capacity shown is with one pump in reserve, per NFPA 99

• All values assume 60Hz motors

• To convert free air capacity (SCFM) to expanded air capacity (ACFM) at 19”Hg, multiply SCFM by 2.74

• Maximum recommended ambient temperature: 95°F for standard systems

• Maximum recommended water temperature: 95°F for standard systems



Liquid Ring Pump Fresh Water Usage (Partial Recirculation)

Horsepower

Water Usage (gpm)

3

1.0

5

2.0

5 [HC]

4.0

7.5

3.5

10

3.5



DataSheet

Description

1DQT(5-30)VM120

Duplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 5-30 Horsepower Pumps, 120 Gallon Vacuum Tank.

1DQT(5-30)VM200

Duplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 5-30 Horsepower Pumps, 200 Gallon Vacuum Tank.

1DQT(5-30)VM240

Duplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 5-30 Horsepower Pumps, 240 Gallon Vacuum Tank.

1TQT(5-30)VM120

Triplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 5-30 Horsepower Pumps, 120 Gallon Vacuum Tank.

1TQT(5-30)VM200

Triplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 5-30 Horsepower Pumps, 200 Gallon Vacuum Tank.

1TQT(5-30)VM240

Triplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 5-30 Horsepower Pumps, 240 Gallon Vacuum Tank.

1QQT(10-30)VM200

Quadruplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 10-30 Horsepower Pumps, 200 Gallon Vacuum Tank.

1QQT(10-30)VM240

Quadruplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 10-30 Horsepower Pumps, 240 Gallon Vacuum Tank.

1QQT(10-30)VM400

Quadruplex, Liquid Ring Pumps - Once Through, Modular with Vertical Tank Mount. 10-30 Horsepower Pumps, 400 Gallon Vacuum Tank.

Product Reviews

(0 Ratings, 0 Reviews)