Daburn's medical dry claw vacuum pump systems deliver the reliability and performance that healthcare facilities demand. These oil-less, continuous duty medical vacuum pumps feature frictionless claw-type compression for clean, contamination-free operation in critical care environments. Available in duplex through hexaplex configurations with pump capacities ranging from 2 to 15 horsepower, each dry claw pump system is fully NFPA 99 compliant and engineered for high efficiency. Multiple mounting options — including vertical stack, horizontal tank, and modular layouts — allow seamless integration into any facility design, making Daburn a trusted source for medical vacuum solutions.
|
Dry Claw Pump Specifications
|
|
Pump Horsepower
|
Capacity (SCFM) @ 19"Hg
|
System Btu/hr
|
System dB(A) Level
|
System FLA
|
|
Pump
|
System
|
208V
|
230V
|
460V
|
380V (50 Hz)
|
|
Duplex
|
|
2
|
16
|
16
|
5,090
|
70
|
15.1
|
15.0
|
7.5
|
6.6
|
|
3
|
21
|
21
|
7,635
|
70
|
20.8
|
20.3
|
10.1
|
9.3
|
|
4
|
29
|
29
|
10,180
|
79
|
26.1
|
24.0
|
12.0
|
12.1
|
|
5
|
38
|
38
|
12,725
|
79
|
33.9
|
30.7
|
15.3
|
13.0
|
|
6.4
|
52
|
52
|
16,288
|
79
|
41.9
|
40.2
|
20.1
|
20.4
|
|
7.5
|
62
|
62
|
19,088
|
79
|
48.4
|
45.6
|
22.8
|
22.3
|
|
8.7
|
78
|
78
|
22,142
|
82
|
56.9
|
53.1
|
26.6
|
26.6
|
|
10
|
102
|
102
|
25,450
|
83
|
70.3
|
68.9
|
34.6
|
35.6
|
|
15
|
130
|
130
|
38,175
|
86
|
96.0
|
83.1
|
41.6
|
47.8
|
|
Triplex
|
|
2
|
16
|
32
|
10,180
|
73
|
22.6
|
22.4
|
11.2
|
9.9
|
|
3
|
21
|
42
|
15,270
|
73
|
31.3
|
30.4
|
15.2
|
14.0
|
|
4
|
29
|
58
|
20,360
|
82
|
39.1
|
35.9
|
18.0
|
18.1
|
|
5
|
38
|
76
|
25,450
|
82
|
50.9
|
46.0
|
23.0
|
19.6
|
|
6.4
|
52
|
103
|
32,576
|
82
|
62.9
|
60.3
|
30.1
|
30.6
|
|
7.5
|
62
|
125
|
38,175
|
82
|
72.6
|
68.4
|
34.2
|
33.4
|
|
8.7
|
78
|
156
|
44,283
|
85
|
85.3
|
79.7
|
39.8
|
40.0
|
|
10
|
102
|
203
|
50,900
|
86
|
105.4
|
103.3
|
51.8
|
53.4
|
|
15
|
130
|
259
|
76,350
|
89
|
144.1
|
124.7
|
62.3
|
71.7
|
|
Quadraplex
|
|
3
|
21
|
63
|
22,905
|
75
|
41.7
|
40.6
|
20.3
|
18.6
|
|
4
|
29
|
87
|
30,540
|
84
|
52.1
|
47.9
|
24.0
|
24.2
|
|
5
|
38
|
113
|
38,175
|
84
|
67.8
|
61.3
|
30.7
|
26.1
|
|
6.4
|
52
|
155
|
48,864
|
84
|
83.8
|
80.3
|
40.2
|
40.8
|
|
7.5
|
62
|
187
|
57,263
|
84
|
96.8
|
91.2
|
45.6
|
44.6
|
|
8.7
|
78
|
233
|
66,425
|
87
|
113.8
|
106.2
|
53.1
|
53.3
|
|
10
|
102
|
305
|
76,350
|
88
|
140.5
|
137.7
|
69.1
|
71.2
|
|
15
|
130
|
389
|
114,525
|
91
|
192.1
|
166.2
|
83.1
|
95.6
|
|
Pentaplex
|
|
10
|
102
|
406
|
101,800
|
89
|
175.7
|
172.1
|
86.4
|
89.0
|
|
15
|
130
|
518
|
152,700
|
92
|
240.1
|
207.8
|
103.9
|
119.5
|
|
Hexaplex
|
|
10
|
102
|
508
|
127,250
|
90
|
210.8
|
206.6
|
103.7
|
106.9
|
|
15
|
130
|
648
|
190,875
|
93
|
288.1
|
249.3
|
124.7
|
143.4
|
|
|
|
|
|
|
|
|
|
|
Notes:
|
|
• System capacity shown is with one pump in reserve, per NFPA 99
|
|
• All values assume 60Hz motors
|
|
• To convert free air capacity (SCFM) to expanded air capacity (ACFM) at 19”Hg, multiply SCFM by 2.74
|
|
• Maximum recommended ambient temperature: 95°F for standard systems
|
|