Browse Categories
PayPal Accept credit cards with QuickBooks Payments
Mailing Lists

Polytron KUIP300 AC-DC Power Supply for Industrial Applications


Price (Each): Call or e-mail for quotes or to order.
Available to Order
Item Number: KUIP300

Industrial Applications

The KUIP300 AC-DC power supply for industrial applications delivers up to 300 watts and up to 360 watts peak power for 5 seconds (typ.) while accepting a universal input of 85 to 264V AC. It comes in four styles: open type (2.09 x 4.00 x 1.26 inches), base plate type (2.44 x 4.60 x 1.56 inches) and enclosed and DIN rail types, both measuring 2.44 x 4.60 x 2.32 inches. Features include adjustable output voltage, high efficiency up to 93 percent, 3,000V AC reinforced insulation, low standby power, low leakage current and an internal EN 55032 Class B filter. The Isolation Class I and Class II units also provide remote ON/OFF and fan speed control, a power good signal and an operating altitude of 5,000m. The RoHS- and REACH-compliant KUIP300 is suitable for OVC III applications, meets the IEC/EN/UL 62368-1 safety standard and offers built-in overcurrent, over voltage, short circuit and over temperature protection.

KUIP300 Series Specification Sheet PDF

Daburn Part
Number

Input Voltage Range
Vdc

Output Voltage
Vdc
Output Current Natural Convection
A
Output Current Forced Air Cooling with 21 CFM
mA
Input Power at No Load
W
Efficiency
%
Maximum Capacitor Load
µF

KUIP300-12S

85-264

12 15 25 0.3 91 20,000

KUIP300-15S

15 12 20 0.3 92 12,000

KUIP300-18S

18 10 16.66 0.3 93 9,000

KUIP300-24S

24 7.5 12.5 0.3 93 2,400

KUIP300-28S

28 6.42 10.71 0.3 93 2,000

KUIP300-36S

36 5 8.33 0.3 93 1,000

KUIP300-48S

48 3.75 6.25 0.3 93 650

KUIP300-53S

53 3.4 5.67 0.3 93 470



Input and Output Specifications:


INPUT

  • Voltage Range:
    • AC Input: 85 - 264Vdc
    • DC Input: 120 - 370Vdc
  • Input Frequency: AC Input: 47 - 63Hz, AC Input
  • Input Current:
    • 100 VAC and full load: 3.9A
    • 240 VAC and full load: 1.6A
  • No Load Input Power
    • 230 Vac, Option F (with Fan): 3 W
    • Others: 0.3 W
  • Leakage Current: 264 Vac: 300µA
  • Power factor: 0.9
  • Start-up time: 2000ms
  • Rise time: 30ms
  • Hold-up time: 115 Vac and 225 W: 10ms
  • Input Inrush Current: 230 Vac: 70A
  • Input Protection: Internal fuse: T5.0A/250Vac

OUTPUT

  • Output Power: 300 W, Forced air cooling
  • Output Peak Power: 360 W
  • Output Peak Power Time: 5 s
  • Output Peak Power Duty: 20%
  • Output Peak Power Average Operation: 50%, % of Full Load
  • Initial Set Voltage Accuracy: 230Vac and Full Load: ±1.0%
  • Line Regulation: Low Line to High Line at Full Load: ±0.2%
  • Load Regulation:
    • No Load to Full Load: ±0.5%
    • 10% to 90% Load: ±0.4%
  • Voltage Adjustability: ±10%
  • Minimum Load: 0%
  • Ripple and Noise (Measured by 20MHz bandwidth with a 1µF/100V 1206 X7R MLCC)
    • 12Vout: 120mVp-p
    • 15Vout: 150mVp-p
    • 18Vout: 180mVp-p
    • 24Vout: 240mVp-p
    • 28Vout: 280mVp-p
    • 36Vout: 360mVp-p
    • 48Vout: 480mVp-p
    • 53Vout: 530mVp-p
  • Temperature Coefficient: ±0.02%/ºC
  • Transient Response Peak Deviation: Load step from 50-75% change at 2.5A/μs: 3% Vout
  • Transient Response Recovery Time: Recovery within 1% Vout: 600μs
  • Over Voltage Protection: % of Vout(nom); Latch mode: 115 - 135
  • Over Load Protection: % of Iout rated; Hiccup mode: 150%
  • Short Circuit Protection: Continuous, automatic recovery
  • Main output Power Good signal
    • Power good, Low (Referenced to "GND")
    • Power off, Open collector
  • Standby Power Supply: 1000mA, Standby and fan power supply total power 8W, 5Vout
  • Fan Power Supply: 500mA, 12Vout

More Specifications: 

 

GENERAL

  • Isolation Voltage:
    • Input to Output, 1 minute (Reinforced insulation): 3,000Vac
    • Input (Output) to F.G.: 1,500Vac
  • Isolation Resistance: 500Vdc, 0.1GΩ
  • Switching Frequency: 230Vac, Full load: 140kHz


ENVIRONMENTAL

  • Operating Ambient Temperature:
    • With derating, Option -F (with Fan): -40-80ºC
    • Others: -40-85ºC
  • Storage Temperature Range:
    • With derating, Option -F (with Fan): -40-80ºC
    • Others: -40-85ºC
  • Over temperature protection: 125°C (Internal thermistor; Hiccup mode)
  • Operating Altitude: 5000m
  • Shock: IEC60068-2-27
  • Vibration: IEC60068-2-6
  • Relative Humidity: Non-condensing, 5% to 95% RH

 

PHYSICAL

  • Design Meet Safety Standard: IEC/EN/UL 62368-1
  • Weight:
    • Open type: 210g (7.40oz)
    • Enclosed type: 318g (11.21oz)
    • Base plate type: 260g (9.17oz)
    • Din rail type: 340g (11.99oz)
  • MTBF: MIL-HDBK-217F Ta=25°C, Full load, 1.056 x 106 hrs
  • Dimensions:
    • Open type: 2.09" × 4" × 1.26"
    • Enclosed type: 2.44" × 4.6" × 2.32"
    • Base plate type: 2.44" × 4.6" × 1.56"
    • Din rail type: 2.44" × 4.6" × 2.32"

 

 EMC CHARACTERISTICS

  • EMI:
    • EN55032 and FCC Part 15
    • Conducted: Class B
    • Radiated: Class A
  • Harmonic Currents: EN61000-3-2, Full load, Class A
  • Voltage Flicker: EN61000-3-3
  • EMS: EN55035
  • ESD: EN61000-4-2, Perf. Criteria A
  • Radiated Immunity: EN61000-4-3, 20V/m, Perf. Criteria A
  • Fast Transient: EN61000-4-4, ±2kV, Perf. Criteria A
  • Surge: EN61000-4-5, DM ±1kV and CM±2kV, Perf. Criteria A
  • Conducted Immunity: EN61000-4-6, 20 Vr.m.s, Perf. Criteria A
  • Power Frequency Magnetic Field: EN61000-4-8, 30 A/m, Perf. Criteria A
  • Dip and Interruptions: EN61000-4-11

 

Product Reviews