P81/240E Series ITE power supplies accept a wide, universal 90-264V AC, 47-63 Hz input range and meet the new edition OVC III overvoltage standard for fixed-installation applications. Three versions are available, depending on output and cooling. The units come in a 4.1 x 2.46 x 1.54-inch package, and they feature an active PFC function, high efficiency up to 94%, 4,250V AC I/O isolation, up to 5,000m altitude operation and a wide operating temperature range of -40 to +80°C with derating. No-load power consumption is <0.5W.
P81/240E Series Specification Sheet PDF
| Daburn Model Number | Max Output Wattage with 8CFM FAN W | Max Output Wattage with Conduction Cooling 6 W | Max Output Wattage with Natural Convection W | Output Current with 8CFM Fan or Conduction Cooling W | Current (Natural Convection) A, Max. |
| P81/240E-12S |
240 |
240 |
210 (100 VAC) 234 (230 VAC) |
20 |
17.5 (at 100 VAC) 19.5 (at 230 VAC) |
| P81/240E-24S |
240 |
240 |
215 (100 VAC) 240 (230 VAC) |
10 |
8.96 (at 100 VAC) 10 (at 230 VAC) |
| P81/240E-48S |
240 |
240 |
215 (100 VAC) 240 (230 VAC) |
5 |
4.48 (at 100 VAC) 5 (at 230 VAC) |
Input and Output Specifications:
Input SpecificationsVoltage, VAC 390-264Check the derating curve for more details.Frequency, Hz47-63Current , A<3.0 Max (115 VAC) <1.5 Max (230 VAC)Full LoadInrush Current, A<45 max="" 115="" vac="" 90="" 230="" td=""><2msLeakage Current , mA<0.75 / 264 VAC (Touch Current)Power FactorPF>0.9 at Full LoadNo Load, W<0.3 (115/230 VAC)
| Output Specifications | | |
| Voltage, V |
12 |
P81/240E-12S |
|
24 |
P81/240E-24S |
|
48 |
P81/240E-48S |
| Voltage Adj Range (VDC), % |
±5 Output Voltage |
|
| Voltage Accuracy, % |
±2 |
|
| Line Regulation, % |
±1 |
|
| Load Regulation, % |
±1 |
|
| Minimum Load, % |
0 |
|
| Maximum Capacitive Load, µF |
8000 |
P81/240E-12S |
|
3000 |
P81/240E-24S |
|
470 |
P81/240E-48S |
| Ripple & Noise, % 1 |
1 % Vout Max. |
|
| Efficiency (at 230VAC), % 5 |
92.5 |
P81/240E-12S |
|
93 |
P81/240E-24S |
|
94 |
P81/240E-48S |
| Hold-up Time (at 115 VAC), ms 2 |
10 ms Min. |
|
| General Specifications | |
| Over Power Protection |
Auto recovery (110-210%), Hiccup Mode |
| Over Voltage Protection |
Auto Recovery |
| Over Temperature Protection |
Auto Recovery |
| Short Circuit Protection |
Protection level 1 (nominal): Continuous, Auto recovery |
|
Protection level 2 (instantaneous high current): Latch |
| Input-Output, VAC 4 |
4250 or 6000 VDC |
| Input-PE, VAC 4 |
2830 or 4000 VDC |
| Output-PE, VAC 4 |
1500 or 2121 VDC |
| Environmental Specifications | |
| Operation Tempature, ºC 9 |
-40... +80 (With derating) |
| Storage temperature, ºC |
-40... +80 |
| Temperature Coefficient, ºC |
±0.05% |
| Altitude During Operation, m |
5000 (OVC II), 4000 (OVC III) |
| Humidity, RH |
20 ~ 90 |
| MTBF |
>400,000 h @ 25ºC (MIL-HDBK-217F, Notice 1) |
| Vibration |
IEC60068-2-6 (10~500Hz, 5G 10min / 1 cycle, 60 min. each along X, Y, Z axes) |
| Shock |
IEC60068-2-27 (Acceleration: 75G ; Pulse duration: 11ms ; Filter: 500Hz) |
| Physical Specifications | |
| Design meet safety standard |
UL / IEC / EN 62368-1 |
| Dimensions, in |
4.1 x 2.46 x 1.54 in (104.0 x 62.5 x 39.2 mm) Tolerance ±0.5mm |
| Weight, g |
365 |
| Cooling Method |
Natural Convection / Conduction Cooling / 8CFM Fan |
|
|
|