RWBH40 Series DC-DC Converters for Railway Applications
|
Available to Order
Item Number: RWBH40
|
RWBH40 Series Specification Sheet PDF
Daburn Part Number |
Input Voltage Range Vdc |
Output Voltage Vdc |
Output Current at Full Load mA |
Input Current at No Load mA |
Efficiency (%) |
Maximum Capacitor Load µF |
RWBH40-110S5 |
36 ~ 160 |
5 |
8 |
10 |
88 |
9,600 |
RWBH40-110S5.1 |
36 ~ 160 |
5.1 |
8 |
10 |
88 |
9,600 |
RWBH40-110S12 |
36 ~ 160 |
12 |
3.333 |
10 |
89 |
1,667 |
RWBH40-110S15 |
36 ~ 160 |
15 |
2.666 |
10 |
90 |
1,066 |
RRWBH40-110S24 |
36 ~ 160 |
24 |
1.666 |
10 |
88.5 |
417 |
RWBH40-110-12 |
36 ~ 160 |
±12 |
±1.666 |
10 |
88 |
±833 |
RWBH40-110-15 |
36 ~ 160 |
±15 |
±1.333 |
10 |
89 |
±533 |
Input and Output Specifications:
|
INPUT
- Operatin input voltage range, Vdc: 36 Min., 110 Typ., 160 Max., 110 Vin (nom)
- Start up voltage, Vdc: 36 Max. 110 Vin (nom)
- Shutdown voltage, Vdc: 32 Min., 34 Typ., 35.8 Max., 110 Vin (nom)
- Start up time, ms:
- 30 Typ., 60 Max., Power up, Constant resistive load
- 30 Typ., 60 Max., Remote ON/OFF
- Input surge voltage, Vdc: 200 Max., 1 second, Max., 110 Vin (nom)
- Input filter: Pi type
- Remote ON/OFF:
- Open or 3 ~ 12Vdc: Positive logic, DC-DC ON
- Short or 0 ~ 1.2Vdc: Standard, DC-DC OFF
- Short or 0 ~ 1.2Vdc: Negative logic, DC-DC ON
- Open or 3 ~ 12Vdc: Option, DC-DC OFF
- -0.5 Min., 0.5 Max.: Input current of Ctrl pin
- 3 Typ.: Remote off input current
|
OUTPUT
- Voltage accuracy, %: ±1
- Line regulation, %: ±0.2, LL to HL at full load, single
- Load regulation, %:
- ±0.5, No load to full load, Single
- -±1, Dual
- Cross regulation, %: ±5, Asymmetrical load 25%/100% FL, Dual
- Voltage adjustability, %:
- ±10: Single Output, Other
- -10 Min., 20 Max.: 15, 24 Vout
- Ripple and noise, mVp-p: Measured by 20MHz bandwidth, with a 1µF/50V X7R MLCC
- 75 Typ.: 5, 5.1 Vout
- 100 Typ.: 12, 15 Vout
- 150 Typ.: 24 Vout
- Temperature coefficient, %/ºC: ±0.02
- Transient response recovery time, μs: 250 Typ., 25% load step change
- Over voltage protection. Vdc: Zener Diode clamp
- 6.2: 5, 5.1 Vout
- 15: 12 Vout
- 20: 15 Vout
- 30: 24 Vout
- Over load protection, %: Percent of Iout rated, Hiccup mode: 150
- Short circuit protection: Continuous, automatic recovery
|
More Specifications:
|
GENERAL
- Isolation Voltage, Vac: 1 minute, input to output, 3,000 Min.
- Isolation resistance, GΩ: 500Vdc, 1 Min.
- Isolation capacitance, pF: 1,000 Max.
- Switching frequency, kHz: 250 Min., 275 Typ., 310 Max.
ENVIRONMENTAL
- Operating ambient temperature °C: With derating, -40 Min. +105 Max.
- Maximum case temperature, °C: +105 Max.
- Over temperature protection, °C: Internal temperature sensor
- Storage temperature range: -55 Min., 125 Max.
- Thermal impedance, °C/W:
- Natural Convection, Without Heat-sink: 11.3 Typ.
- With Heat-sink: 6.6 Typ.
- Thermal shock: MIL-STD-810F
- Shock: EN61373, MIL-STD-810F
- Vibration: EN61373, MIL-STD-810F
- Relative humidity: 5% to 95% RH
|
PHYSICAL
- Design meet safety standard: IEC/EN/UL 62368-1, EN505155, EN45545-2, UL:E193009
- Case material: Non-conductive black plastic
- Base material: Non-conductive black plastic
- Potting material: Silicone, (UL94 V-0)
- Weight: 32g (1.13oz)
- MTBF: 1.253 × 106 hrs, MIL-HDBK-217F, Full Load
EMC CHARACTERISTICS
- EMI:
- EN55032, EN50121-3-2, Without external components, Class A
- With external components, Class B
- EMS: EN55024, EN50121-3-2
- ESD: EN61000-4-2, Air ±8kV and Contact ±6kV, Perf. Criteria A
- Radiated immunity: EN61000-4-3, 20V/m, Perf. Criteria A
- Fast transient: EN61000-4-4, ±2KV, Perf. Criteria A
- Surge: EN61000-4-5, ±2KV, Perf. Criteria A
- Conducted immunity: EN61000-4-6, 10Vr.m.s, Perf. Criteria A
- Power frequency magnetic field: EN61000-4-8, 100A/m continuous; 1000A/m 1 second, Perf. Criteria A
|
|
Product Reviews
|
|