Shielded Computer & Audio
MIL-W-16878 - Plastic Jacket, 600V · 105°C - One or more conductors stranded tinned copper, PVC insulation, color coded, clear Nylon (polyamide) jacket. Conductors are cabled, overall braided tinned copper shield. (min. 90% coverage.).
|
Shielded & Unshielded - Single conductor #23 (7) Soft tinned copper conductors insulated with .010'" Soft PVC. Multi-Concuctor items: Conductors are twisted. For Shielded items: Conductors are twisted and shielded with braided tinned copper overall.
|
Each conductor tinned copper, polyethylene insulation - color coded. Conductors are cabled with fillers, textile wrapped, tinned copper braided shield, gray polyvinyl jacket overall. Operating Temperature: -20°C to +80°C. 600 Volts.
|
Each Daburn modular cord is 28 AWG 7/36 soft copper, color coded with an overall PVC jacket and modular plugs at each end. Shielded constructions use an overall aluminum/polyester shield and drain wire.
|
Each conductor is #28 AWG 7/36 tinned copper, color coded, .009" wall of semi-rigid PVC (UL Style 1061, CSA Type S-R PVC). Conductors are twisted in pairs.
|
Each conductor is #28 AWG 7/36 tinned copper, color coded, .009" wall of semi-rigid PVC (UL Style 1061, CSA type S-R- PVC). Conductors are twisted.
|
UL Style 2464 - Individually Polyester Foil Shielded Pairs - Each conductor is #22 AWG solid tinned copper, insulated with .013" color coded, vinyl cabled in pairs. Each pair is shielded with aluminum polyester foil and stranded tinned copper drain wire.
|
U/L Style 2493 - Individually Polyester Foil Shielded Pairs RS 232 - Each conductor is #22 AWG stranded tinned copper, insulated with color coded, high density polyethylene and twisted into pairs. Each pair is shielded with aluminum polyester foil.
|
Each conductor stranded tinned copper, color coded PVC. Where indicated, T.C. braid shield, paired. Gray polyvinylchloride jacket overall. Used for station to station wiring to eliminate cross-talk.
|
Four conductor #22 stranded tinned copper, color coded high density polyethylene insulation, aluminum mylar foil shield and stranded T. C. drain wire over one pair. Chrome vinyl jacket overall. Suitable for balanced systems, small O.D., less bulk.
|
Each conductor is #24 AWG 7/32 tinned copper, color coded with .009" wall of semi-rigid PVC (UL Style 1061, CSA Type S-R- PVC). Conductors are twisted in pairs. Overall aluminum/polyester foil shield & 7 strand tinned copper drain wire. Gray PVC jacket.
|
Each conductor is #24 AWG 7/32 tinned copper, color coded, .009" wall of semi-rigid PVC (UL Style 1061, CSA Type S-R PVC). Conductors are twisted in pairs.
|
UL Style 1108, 2095 · VW-1 · CL2 - Each conductor is tinned copper with plastic insulation. Conductors are color coded and twisted then wrapped with spiral tinned copper shielding. Jacket is gray polyvinylcholoride.
|
UL 2092, 2093, 2094† - Each conductor is stranded tinned copper-color coded with polyethylene insulation, conductors are twisted with an overall aluminum/polyester foil shield and drain. Gray PVC jacket. Drainwire provides quick and easy grounding.
|
UL STYLE 2095, 1108 · VW-1 · CL2 - Each conductor is stranded tinned copper with PVC insulation, color coded, twisted, braided tinned copper shield and an overall gray vinyl jacket. The braided tinned copper construction allows ease of pigtailing.
|
Each conductor is #24 AWG 7/32 tinned copper, color coded, .009" wall of semi-rigid PVC (UL Style 1061. CSA Type S-R PVC). Conductors are twisted. Overall aluminum/polyester foil shield and 7 strand tinned copper drain wire.
|
Multipair To UL Style 2464 Cl2 - Each conductor is #24 AWG 7/32 tinned copper, color coded, .009" wall of semi-rigid PVC (UL Style 1061, CSA Type S-R- PVC). Conductors are twisted in pairs.
| |
|
|